- priority: 5 --> 2
Certain characters in a location cause the application to throw an exception. Probably due to terribly coding of the XML parser/builder.
Steps to reproduce:
-Edit Location
-Add Location
-Enter any name with an apostraphe, such as Dante's Gate to Hell
-Watch the exception spew forth.
************** Exception Text **************
System.Xml.XmlException: Root element is missing.
at System.Xml.XmlTextReaderImpl.Throw(Exception e)
at System.Xml.XmlTextReaderImpl.ThrowWithoutLineInfo(String res)
at System.Xml.XmlTextReaderImpl.ParseDocumentContent()
at System.Xml.XmlTextReaderImpl.Read()
at System.Xml.XmlLoader.LoadDocSequence(XmlDocument parentDoc)
at System.Xml.XmlLoader.Load(XmlDocument doc, XmlReader reader, Boolean preserveWhitespace)
at System.Xml.XmlDocument.Load(XmlReader reader)
at System.Xml.XmlDocument.LoadXml(String xml)
at DataComm.XMLParser.initialize(String xmlIN) in C:\cmsc435\sandbox\wits_client\WITS Client Application\DataComm Module\XMLParser.cs:line 571
at DataComm.XMLParser.success_failure(String xmlIN) in C:\cmsc435\sandbox\wits_client\WITS Client Application\DataComm Module\XMLParser.cs:line 21
at DataComm.Commands.addLocation(Location locationIN) in C:\cmsc435\sandbox\wits_client\WITS Client Application\DataComm Module\Commands.cs:line 319
at GUI.EditLocation.locationGrid_CellContentClick(Object sender, DataGridViewCellEventArgs e) in C:\cmsc435\sandbox\wits_client\WITS Client Application\GUI Module\EditLocation.cs:line 141
at System.Windows.Forms.DataGridView.OnCellContentClick(DataGridViewCellEventArgs e)
at System.Windows.Forms.DataGridView.OnCommonCellContentClick(Int32 columnIndex, Int32 rowIndex, Boolean doubleClick)
at System.Windows.Forms.DataGridViewCell.OnMouseUpInternal(DataGridViewCellMouseEventArgs e)
at System.Windows.Forms.DataGridView.OnCellMouseUp(DataGridViewCellMouseEventArgs e)
at System.Windows.Forms.DataGridView.OnMouseUp(MouseEventArgs e)
at System.Windows.Forms.Control.WmMouseUp(Message& m, MouseButtons button, Int32 clicks)
at System.Windows.Forms.Control.WndProc(Message& m)
at System.Windows.Forms.DataGridView.WndProc(Message& m)
at System.Windows.Forms.Control.ControlNativeWindow.OnMessage(Message& m)
at System.Windows.Forms.Control.ControlNativeWindow.WndProc(Message& m)
at System.Windows.Forms.NativeWindow.Callback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam)
************** Loaded Assemblies **************
mscorlib
Assembly Version: 2.0.0.0
Win32 Version: 2.0.50727.42 (RTM.050727-4200)
CodeBase: file:///C:/WINDOWS/Microsoft.NET/Framework/v2.0.50727/mscorlib.dll
----------------------------------------
WITS Client Application
Assembly Version: 1.0.0.0
Win32 Version: 1.0.0.0
CodeBase: file:///C:/cmsc435/sandbox/wits_client/WITS%20Client%20Application/bin/Debug/WITS%20Client%20Application.exe
----------------------------------------
System.Windows.Forms
Assembly Version: 2.0.0.0
Win32 Version: 2.0.50727.42 (RTM.050727-4200)
CodeBase: file:///C:/WINDOWS/assembly/GAC_MSIL/System.Windows.Forms/2.0.0.0__b77a5c561934e089/System.Windows.Forms.dll
----------------------------------------
System
Assembly Version: 2.0.0.0
Win32 Version: 2.0.50727.42 (RTM.050727-4200)
CodeBase: file:///C:/WINDOWS/assembly/GAC_MSIL/System/2.0.0.0__b77a5c561934e089/System.dll
----------------------------------------
System.Drawing
Assembly Version: 2.0.0.0
Win32 Version: 2.0.50727.42 (RTM.050727-4200)
CodeBase: file:///C:/WINDOWS/assembly/GAC_MSIL/System.Drawing/2.0.0.0__b03f5f7f11d50a3a/System.Drawing.dll
----------------------------------------
System.Configuration
Assembly Version: 2.0.0.0
Win32 Version: 2.0.50727.42 (RTM.050727-4200)
CodeBase: file:///C:/WINDOWS/assembly/GAC_MSIL/System.Configuration/2.0.0.0__b03f5f7f11d50a3a/System.Configuration.dll
----------------------------------------
System.Xml
Assembly Version: 2.0.0.0
Win32 Version: 2.0.50727.42 (RTM.050727-4200)
CodeBase: file:///C:/WINDOWS/assembly/GAC_MSIL/System.Xml/2.0.0.0__b77a5c561934e089/System.Xml.dll
----------------------------------------
************** JIT Debugging **************
To enable just-in-time (JIT) debugging, the .config file for this
application or computer (machine.config) must have the
jitDebugging value set in the system.windows.forms section.
The application must also be compiled with debugging
enabled.
For example:
<configuration>
<system.windows.forms jitDebugging="true" />
</configuration>
When JIT debugging is enabled, any unhandled exception
will be sent to the JIT debugger registered on the computer
rather than be handled by this dialog box.