#697 Standard design with Sips panels is a concrete block wall

2013August
Verified
None
High
Comp.Error
2013&2016
CBECCr
2016-08-10
2016-06-23
Ken Nittler
No

These files were forwarded to me from a CBECC-Res user under 2016 Alpha3. I did a quick check in 2013 4b and see the same problem.

These two files are the same except on references a standard wood frame wall and the other a SIPS panel. It would seem they should have the same standard design, but they do not. I looked into .cse file and found that the standard design for the SIPS panel case appears to be a block wall with different areas than the wood frame case. The building summary files confirm the standard design is based on a block wall.

2 Attachments

Discussion

  • Ken Nittler

    Ken Nittler - 2016-07-06
    • Priority: Medium --> High
     
  • Scott Criswell

    Scott Criswell - 2016-07-19
    • assigned_to: Bruce Wilcox --> Lukas Hovee
     
  • Sandeep Doddaballapur

    Fix for ticket #697: Committed to the repo at Rev #620.
    Standard design with Sips panels has been changed to Wood frame wall.
    The standard .ibd and .cse files of the model with SIPS wall have been compared with those from the model with wood-frame wall and were found to adequately match or were identical.

     

    Last edit: Sandeep Doddaballapur 2016-08-03
  • Lukas Hovee

    Lukas Hovee - 2016-08-03
    • status: New --> Fixed
     
  • Dee Anne Ross

    Dee Anne Ross - 2016-08-10
    • status: Fixed --> Verified
     