Menu

#1221 Fenestration Average U-factor is reporting incorrect value

2019.1.3
Verified
None
Critical
Comp.Error
2019
Unaffected
CBECCr
2020-07-10
2020-05-11
No

This file has windows with 0.30 U-factor (one French door with 0.29 U-factor), no skylights. It is reporting 0.34 as the average U-factor in XML/CF1R when it should be 0.30 at most <a17_ufactorfenestrationaverage>0.34</a17_ufactorfenestrationaverage> [if it matters, file was originally an EnergyPro file].

3 Attachments

Discussion

  • Scott Criswell

    Scott Criswell - 2020-05-19
    • status: New --> Fixed
     
  • Scott Criswell

    Scott Criswell - 2020-05-19

    fixed in SVN r1785
    Calcs in setting A17_UFactorFenestrationAverage were inconsistent in referencing garage windows (included in area-weighted U-factor sum but excluded from final area divisor).
    The CF1R now reports the average U-factor for all New/Altered windows & skylights of conditioned zones.

     
  • Dee Anne Ross

    Dee Anne Ross - 2020-05-22
    • status: Fixed --> Verified
     
MongoDB Logo MongoDB