#1216 Underground Floor reporting missing from CF1R

2019.1.3
Verified
None
Critical
Doc.Error
2019
Unaffected
CBECCr
2020-07-10
2020-04-20
No

Discussion

  • Dee Anne Ross

    Dee Anne Ross - 2020-04-20
    • Attachments has changed:

    Diff:

    --- old
    +++ new
    @@ -3,4 +3,5 @@
     Epro7 2020-06.new-3a No Basement Slab in Report.ribd16x (164.8 kB; application/octet-stream)
     Epro8 2020-06.new-3a No Basement Slab in Report - CF1RPRF01E-BEES.pdf (211.8 kB; application/pdf)
     Epro8 2020-06.new-3a No Basement Slab in Report - CF1RPRF01E.xml (349.1 kB; text/xml)
    +Epro8 2020-06.new-3a No Basement Slab in Report.ribd19x (182.8 kB; application/octet-stream)
     T-24-LAPANTE-APR-9-2020 No Attic - AnalysisResults-BEES.pdf (183.0 kB; application/pdf)
    
     
  • Rob Hitchcock

    Rob Hitchcock - 2020-05-18

    There are currently no rules to export this surface type to the CF1R XML.

    The properties of "Underground Floor" do not really match CF1R XSD elements in either Section_J (opaque surfaces) or Section_P (slab floors).

    So, do we need a new section to report this surface type? If so, what properties of "Underground Floor" should be reported in this new section?

     
  • Rob Hitchcock

    Rob Hitchcock - 2020-05-19

    More CEC input needed:

    A. The P05 insulation elements for Section_P seem to have three choices: 1. P05a AND P05c, 2. P05b AND P05c, 3. NotApplicable ("n/a"). Can you confirm that this is the case so that the CF1R XSD and rules can include these choices?

    B. Should Underground Floors also be included in Section_Mm (SLAB FLOORS - VERIFIED AND ALTERED)?

     
  • Dee Anne Ross

    Dee Anne Ross - 2020-05-21

    A. Underground floors cannot be insulated, and no input for perimeter. Please make both P04 (if you can) and P05 "n/a" (Note: P06 and 07 are not choices). P08 can have a status (new, altered, existing) but with no ability to insulate. This means P10a should be n/a.

    B. No do not include underground floors in Section Mm because there is no input for the existing construction (it's moot).

     
  • Rob Hitchcock

    Rob Hitchcock - 2020-05-26
    • status: New --> 80%Done
    • assigned_to: Rob Hitchcock --> Robert Scott
     
  • Rob Hitchcock

    Rob Hitchcock - 2020-05-26

    r1793: Added export of Underground Floors to CF1RPRF Section_P SLAB FLOORS

    Report processing modifications are required to address new CF1RPRF XSD P05a_NotApplicableMessage and P05c_NotApplicableMessage elements

     
  • Robert Scott

    Robert Scott - 2020-06-19

    The instructions for displaying this table indicate it should be the same as the 2016 report version. In this there are either 7 or 9 columns (the additional 2 are Status and Verified used with EAA). What is confusing are the elements P10To11ColumnLabel, P10a, P10b, P10c, and P11_SlabCarpetedFraction. P10To11ColumnLabel has the text 'Existing Conditions' but the underground example is 'NewConstruction' where one row of data includes a value for P10a. This seems inconsistent with making this table layout the same as that for 2016. Some clarification would be helpful...

     
  • Robert Scott

    Robert Scott - 2020-06-25
    • status: 80%Done --> Fixed
     
  • Robert Scott

    Robert Scott - 2020-06-25

    Mods to columns to match xml and maintain layout as with the 2016 version.

     
  • Dee Anne Ross

    Dee Anne Ross - 2020-06-25
    • status: Fixed --> Verified
     