#1003 Treatment of room heatpumps and air conditioners

2019.1.3
Verified
None
Critical
Enhancement
2019
Unaffected
CBECCr
2020-09-11
2018-04-02
Ken Nittler
No

Right now room heatpumps and air conditioners are treated the same as mini split systems. They need to be split into their own category and have the standard design modeled with minimum efficiency for their categories and no ducts.

1 Attachments

Discussion

1 2 > >> (Page 1 of 2)
  • Ken Nittler

    Ken Nittler - 2018-04-02

    Related to ticket #971

     
  • Ken Nittler

    Ken Nittler - 2018-04-27

    DeeAnne notes this same issue applies to wall furnaces

     
  • Ken Nittler

    Ken Nittler - 2018-04-30
    • Priority: High --> Critical
    • Milestone: 2016.next --> 2016.3.1
     
  • Ken Nittler

    Ken Nittler - 2018-04-30

    Meeting needs to be scheduled to discuss. Ticket replated to #971. May need to split into two tickets - one for proposed inputs and a second for standard design

     
  • Ken Nittler

    Ken Nittler - 2018-06-07
    • Priority: Critical --> High
     
  • Ken Nittler

    Ken Nittler - 2018-06-07

    demoted based on 05/11 email from Larry increasing priority of 1022 while reducing priority of 1003 and 971

     
  • Ken Nittler

    Ken Nittler - 2018-06-20
    • Milestone: 2016.3.1 --> 2016.next
     
  • Ken Nittler

    Ken Nittler - 2018-06-20

    Moving to 2016.Next as not part of 2016.3.1

     
  • Dee Anne Ross

    Dee Anne Ross - 2018-11-06
    • Milestone: 2016.next --> 2019.next
     
  • Dee Anne Ross

    Dee Anne Ross - 2019-03-08

    Combine with work in Ticket 971.

     
  • Dee Anne Ross

    Dee Anne Ross - 2019-05-30
    • Priority: High --> Critical
     
  • Dee Anne Ross

    Dee Anne Ross - 2019-05-30

    See also 971 about interface.

     
  • Scott Criswell

    Scott Criswell - 2020-08-20
    • status: New --> 50%Done
    • assigned_to: Ken Nittler --> Scott Criswell
    • Version: 2016&2019 --> 2019
    • Milestone: 2019.next --> 2019.1.3
     
  • Scott Criswell

    Scott Criswell - 2020-08-20

    initial round of ruleset, defaulting and UI mods checked into SVN @ r1910

    • switch SglPkgVertAirCond and SglPkgVertHeatPump from always ductless to always ducted (and now expose CFM/ton input)
    • hide CFM/ton input for RoomAirCond, RoomHeatPump and PkgTermAirCond
    • added refrigerant charge input (for reporting) to the PkgTermAirCond, PkgTermHeatPump, SglPkgVertAirCond and SglPkgVertHeatPump
    • replaced HSPF, SEER & EER inputs for RoomHeatPump with (new properties) HeatPower (watts) and CEER and replaced EER w/ CEER for RoomAirCond
    • updated default/minimum efficiencies for ALL above-listed equipment types
      REPORTING changes to follow later
     
  • Scott Criswell

    Scott Criswell - 2020-08-20

    spreadsheet from CEC/TF detailing mods to be addressed by this ticket

     
  • Scott Criswell

    Scott Criswell - 2020-08-24
    • status: 50%Done --> 60%Done
    • assigned_to: Scott Criswell --> Michael Shewmaker
     
  • Scott Criswell

    Scott Criswell - 2020-08-24

    another ruleset/screen mod checked into SVN @ r1912 -
    removed Refrig Charge selection for PTAC, PTHP, SglPkgVertAirCond & SglPkgVertHeatPump and hardwire verified refrig charge simulation benefit for these systems.

    Reassigning tic to CEC/MS in order for CF1R reporting additions/changes to be identified

     
  • Michael Shewmaker

    • assigned_to: Michael Shewmaker --> Scott Criswell
     
  • Scott Criswell

    Scott Criswell - 2020-08-26
    • assigned_to: Scott Criswell --> Rob Hitchcock
     
  • Scott Criswell

    Scott Criswell - 2020-08-26

    re-assigning to RH to coordinate reporting updates

     
  • Rob Hitchcock

    Rob Hitchcock - 2020-08-28
    • status: 60%Done --> 90%Done
    • assigned_to: Rob Hitchcock --> Robert Scott
    • Attachments has changed:

    Diff:

    --- old
    +++ new
    @@ -0,0 +1 @@
    +HeatPumpReportProperties.xlsx (10.3 kB; application/vnd.openxmlformats-officedocument.spreadsheetml.sheet)
    
     
  • Rob Hitchcock

    Rob Hitchcock - 2020-08-28

    r1920: Revised reporting in Section_X and Section_Y, including restricted output of properties based on HP type as documented in attached spreadsheet.
    Consistent XSD mods committed in r1918 with the exception of minor additional edits requested.
    Report processing mods are required to be consistent with latest rules and XSD.

     
  • Robert Scott

    Robert Scott - 2020-09-03
    • status: 90%Done --> Fixed
     
  • Robert Scott

    Robert Scott - 2020-09-03

    Posted revisions to the CF1R to address these issues. Should be checked for central, ductless and room HP.
    @michaelshewmake - The spreadsheet CBECC New HVAC Problems.xlsx says that Room Heat Pump should not display Heat Capacity 17 and the xml does not contain a value for that column. Should there also be a "not applicable" choice for Y06_HeatPumpHeatCapacity17F?

     