#4 GUI MIDI event tracking damages control interface

closed
None
5
2007-04-24
2007-03-20
No

When the GUI is linked into the MIDI channel to allow for controller automation and note on/off tracking then the interface control of various midi parameters fail. The effect is almost as if the GUI controls and keyboard manage one synth but the master keyboard manages another with a separate set of paramters.

Discussion

  • Nick Copeland

    Nick Copeland - 2007-04-23

    Logged In: YES
    user_id=1426398
    Originator: YES

    The MIDI library would change the operational status of the interface from running to library testing, this was done to prevent the GUI from sending note on/off messages again over its own interface to the engine. Under certain circumstances this state would not be reset.

     
  • Nick Copeland

    Nick Copeland - 2007-04-23
    • status: open --> pending
     
  • Nick Copeland

    Nick Copeland - 2007-04-24
    • status: pending --> closed
     
  • Nick Copeland

    Nick Copeland - 2007-04-24

    Logged In: YES
    user_id=1426398
    Originator: YES

    Resolution should now be in the 0.9.6-169 posted yesterday.

     