v0.12p3 (2003-04-03) Herbert Straub
* BUGFIX: array-info does'nt display correct
informations for
logical drives > 1. Add unit nr in cciss_info.c,
cciss_cmd.c
see
http://members.aon.at/hstraub/linux/array-info/index.html
Example:
Compaq Smart Array 5i
Firmware revision : 1.92
Rom revision : 1.92
2 logical drives configured.
Logical drive 0 :
Fault tolerance : RAID 1 (Mirroring)
Size : 33.91 GiB (71122560 blocks
of 512 bytes)
Status : Logical drive is ok
Logical drive 1 :
Fault tolerance : RAID 1 (Mirroring)
Size : 33.91 GiB (71122560 blocks
of 512 bytes)
Status : Logical drive is ok
Patched Version:
Compaq Smart Array 5i
Firmware revision : 1.92
Rom revision : 1.92
2 logical drives configured.
Logical drive 0 :
Fault tolerance : RAID 1 (Mirroring)
Size : 33.91 GiB (71122560 blocks
of 512 bytes)
Status : Logical drive is ok
Logical drive 1 :
Fault tolerance : RAID 5
Size : 67.83 GiB (142245120 blocks
of 512 bytes)
Status : Logical drive is ok