  • Archie Archie posted a comment on discussion Help

    You have to be a member of the AdvancedHMI forum to see the beta testing forum

  • aris sugi aris sugi posted a comment on discussion Help

    hi, I'm using advancedhmi version 3.99x now, it is a great hmi program, i can learn so many thing with this program. anyone know is there any update ? i have read in the forum there is beta version can anyone send me download link of the 3.99y beta ? i have been go to the advancedhmi forum but did'nt find the download link thank you aris

  • Archie Archie posted a comment on discussion Help

    To the best of my knowledge the first SLC 5/05 processors came out before Ethernet/IP was developed. If you dissect the ABEthernet packet, you can see how it was the start and evolved into what is now Ethernet/IP. I can't imagine anyway a ABEthernet processor could hold a CIP (Ethernet/IP) connection, especially considering it is a different TCP/IP port.

  • Joseph Cauley Joseph Cauley posted a comment on discussion Help

    I asked the question and our maintenance team did change out the processor. They say it was 3 weeks ago and that it was working for at least a week since it was changed out up until the power outage this Monday. We're also requisitioning for a new processor and this replacement should fix our issue. Perhaps the power outage reset something that was allowing the CIP connection to be maintained somehow. Thanks, MC

  • Joseph Cauley Joseph Cauley posted a comment on discussion Help

    Though I don't disagree that it sounds like that, it seems very inplausable; I will ask the question though. The Ethernet/IP driver does not connect to it. Interestingly, a computer that utilizes Ethernet/IP driver exclusively was showing the PLC but with an X implying that it had seen it before but no longer sees it and it would not reconnect to it using that driver but it would connect to it using the Ethernet Device driver (where you type in the specific IP address). Do you think it's possible...

  • Archie Archie posted a comment on discussion Help

    Port 2222 is an older protocol, not Ethernet/IP. The early versions of the SLC 5/05 did not support Ethernet/IP AdvancedHMI does not support that older protocol. In RSLinx try using the Ethernet/IP driver (not the Ethernet driver) to see if it works. I am going to take a wild guess and say that if it worked before, then someone swapped out your SLC processor with an older processor.

  • Joseph Cauley Joseph Cauley posted a comment on discussion Help

    The wireshark capture here is interesting i guess. It's filtered again for only that PLC. I have RSLinx running and we can see that every RSLinx communication (port 62304 to 2222) is successful and every BasicLabel communication (Dynamic port to 44818) is not successful. Perhaps this is a hint?

  • Joseph Cauley Joseph Cauley posted a comment on discussion Help

    The original wireshark image was showing all traffic that involved the 10.60.48.215 IPAddress, the PLC. I opened up the AdvancedHMIv35 solution with a single BasicLabel (the one that's currently saying cannot connect and No response from Forward Open) and ran wireshark filtering for only the CIP protocol. There is mention of two IP addresses that are not mine; I'm not entirely sure what they are but they continue to occur even when the BasicLabel app is not running so I assume they're unrelated....

  • Archie Archie posted a comment on discussion Help

    One quick thing to try... In the driver properties, reduce the CIPConnectionSize to 200. Some older PLCs can't handle the 508

  • Archie Archie posted a comment on discussion Help

    The Wireshark screen capture isn't enough for me to diagnose the problem. You can try adding "cip" in the filter to see only the traffic of it talking to the PLC

  • Joseph Cauley Joseph Cauley posted a comment on discussion Help

    I switched to the drivers to what i downloaded yesterday. The parent solution was labeled v35 so I think that's the one you are referring to. The version numbers actually decreased so maybe I've missed something: AdvancedHMIControls 3.9.9.24 AdvancedHMIDrivers 3.9.9.24 MfgControl.AdvancedHMI.Controls 1.0.0.0 MfgControl.AdvancedHMI.Drivers 3.99.19.2 Never the less, the issue persists. Also, F8:8 isn't necessarily the issue. I have not found success in reading anything from the PLC though, again, the...

  • Archie Archie posted a comment on discussion Help

    Ok. That's 3.99y Beta 10. The beta is now up to 35. You would need to go to the AdvancedHMI forum to download the latest beta. I can test the F8:8, but it will take me a couple hours to get to everything to set it up.

  • Joseph Cauley Joseph Cauley posted a comment on discussion Help

    The test in the image above is using the following: AdvancedHMIControls 3.9.9.2510 AdvancedHMIDrivers 3.9.9.2510 MfgControl.AdvancedHMI.Controls 1.0.0.0 (says Runtime Version v4.0.30319 if that's more helpful) MfgControl.AdvancedHMI.Drivers 3.99.19.7 I downloaded the latest drivers from the website in order to do the test that the wireshark data is based on. The BasicLabel is on the black form screen that was included in the solution downloaded. Thanks, MC

  • Archie Archie posted a comment on discussion Help

    What version of AdvancedHMI are you using? If not using at least 3.99x, I would recommend a quick test witrh that version.

  • Joseph Cauley Joseph Cauley posted a comment on discussion Help

    Archie, I wanted to provide one other detail in the attachment below. As you can see, when a direct read is attempted on one of the SLC 5/05 PLCs, there is no issue but yet the other throws a NullReference exception although for each, you can see valid data in both of the F8:8 PLC addresses using RSLinx. Thanks, MC

  • Joseph Cauley Joseph Cauley posted a comment on discussion Help

    Archie, Thanks for the quick reply. I have used wireshark to observe that there does appear to be an issue but I apologize for I am not network savvy enough to have an "ah ha!" moment looking at it. The attachment shows a filtered log of 1 BasicLabel attempting to update itself and presenting the messages mentioned in the above message. The real head scratcher for my team and I is that RSLinx allows us to view data but our AdvancedHMI drivers are not having the same success which leads us to believe...

  • Archie Archie posted a comment on discussion Help

    No settings that I am aware of could change. I would do a WireShark to look at the traffic

  • Joseph Cauley Joseph Cauley posted a comment on discussion Help

    I am having trouble communicating with a SLC-5/05 PLC. There was a power outage and although we are having no trouble connecting to the PLC using RSLinx, our HMIs built with AdvancedHMI drivers are getting no results. The basic labels state: Could not connect to xx.xx.xx.xx, port 44818. Timed out No response from Forward Open When doing a direct .Read, the response is: Read Failed - No Response We are able to view the values on the PLC through RSLinx data monitor and log into it using RSLogix 500....

  • Joseph Cauley Joseph Cauley posted a comment on discussion Help

    Thanks for the feedback. Your suggestion was exactly what the issue was.

  • Archie Archie posted a comment on discussion Help

    Route paths must always be in groups of pairs. So you do need the ,0 on the end of what you have. My guess is that your L1 processor does not support a 508 CIP connection size. Try reducing that to 100

  • Joseph Cauley Joseph Cauley posted a comment on discussion Help

    I followed the ifnormation described below as best as I could but have still been unsuccessful at getting any reads from a PLC begin a controlnet module. https://advancedhmi.com/documentation/index.php?title=Routing_Paths EthernetIPforCLX plctest = new EthernetIPforCLX(); plctest.IPAddress = "10.60.48.211"; plctest.RoutePath = "1,0,2,3,1"; plctest.ProcessorSlot = 0; CLXTag[] tags = plctest.GetTagList(); I've tried this with a ",0" at the end of the path to signify the processer location as well in...

  • m s m s posted a comment on discussion Help

    Hi this is Mike i am doing a very first try at advanced HMI on a 5/04 i think i do not have all params sut up correct on simple push button i am set up on one of the old blue 4 slot SLC trainers my pgm works on trainer push button light goes on push other button light goes off . when i have the HMI on screen i push button light and on screen comes on (cool) and the button on screen reacts i push other button light goes off and other button on screen reacts but when t try and click buttons on screen...

  • Michael Freed Michael Freed posted a comment on discussion Open Discussion

    Problem solved. You need to install the correct "Workload" in Viual Studio. I was missing Universal Windows Platform development.

  • Michael Freed Michael Freed posted a comment on discussion Open Discussion

    Hello, I admit I am rather new to VS 2019 but I am finding my way. So this might be a very simple question. How do you make a new Form? So far the project opens and defaults to MainForm.vb and Page2.vb. I havn't been able to make new forms. Right clicking on the AdvancedHMI Project allows me to: Add->Windows Form->Add New Item - AdvancedHMI window. In the Add New Item - Advanced HMI window there is no option for a Form Item. I suspect that there is some setting somewhere that I need to enable, but...

  • Archie Archie posted a comment on discussion Help

    DF1Comm is from a very old version. Go to the AdvancedHMI web site and get the latest version

  • Hasala Senevirathne Hasala Senevirathne posted a comment on discussion Help

    There is a issue with timer's tag mapping . If you read T4:0.ACC it actually reads the .PRE- preset value. But writing to the .PRE works normally. eg: label1.text = DF1Comm1.ReadAny("T4:0.ACC") // This actually reads T4:0.PRE

  • AdvancedHMI AdvancedHMI released /advancedhmi/3.5/AdvancedHMI.txt

  • AdvancedHMI AdvancedHMI released /advancedhmi/3.5/SFdepart.txt

  • Bui Thanh Trung Bui Thanh Trung posted a comment on discussion Help

    Hi, Do any one have exp/example code to do Subscribe with 2D array using EthernetCLX Driver? Thank you so much!

  • AdvancedHMI AdvancedHMI released /advancedhmi/3.5/SampleProjects/SaveDataTableAndRestoreCLX.zip

  • Heinzou Heinzou posted a comment on discussion Help

    Hello I'need a "ejector" symbol for my ihm where I'can buy it ??

  • Heinzou Heinzou posted a comment on discussion Help

    Ok I'look this thanks you very much

  • Archie Archie posted a comment on discussion Help

    Dd you follow the Quick Start guide that is included with the project? Or go to the AdvancedHMI web site and get it from the link on the main page.

  • Heinzou Heinzou posted a comment on discussion Help

    if you just have a sample code with gauge and button for exemple I think I will succeed in deceiving

  • Heinzou Heinzou posted a comment on discussion Help

    Yes, and I want to devellop in C#

  • Archie Archie posted a comment on discussion Help

    Community Edition?

  • Heinzou Heinzou posted a comment on discussion Help

    I am using Visual studio 2017

  • Archie Archie posted a comment on discussion Help

    AdvancedHMI does not require activation. Is it Visual Studio you are trying to activate? What version of Visual Studio are you using?

  • Heinzou Heinzou posted a comment on discussion Help

    Hello I start in the supervision and I would like to activate advancehmi on visual studio but I can not reach you can tell me the procedure to follow thank you sorry for my english I'm french and I try to make myself understood lol

  • Archie Archie posted a comment on discussion Help

    Set the ComComponent property to point to your driver instance

  • Eduardo Calles Eduardo Calles posted a comment on discussion Help

    Hello I am trying to connect with Kepware/KEPServerEX without sucess, First of all, I have successfullly installed Kepware on a Virtual Machine and connected to an Omron PLC. I grabbed the driver " opcDaCom1" and placed it on my Form1 project on Visual Studio C# project. On the following "opcDaCom1" properties , I typed what's between the following quotation marks: OPCServer = "Kepware.KEPServerEX.V6" OPCServerPath = "opc.tcp://172.19.32.50:49320" Next, I used a BasicIndicator and typed for the PLCAddressSelectColor2...

  • Eduardo Calles Eduardo Calles modified a comment on discussion Help

  • Eduardo Calles Eduardo Calles posted a comment on discussion Help

    Hello I just grab the driver "omronEthernetFINSCom1" and place it on my Form1 project on Visual Studio C# project. I typed my address of my PLC on the IP address, But, I am not so sure what is the format of my tag, For example on the CX-Programmer, my tag address is 3.13, so I just type 3.13 for my PLCAddressSelectColor2 for my BasicIndicator properties, but this is not working. When I play the application, my indicator doesn't show the correct state, but it shows a message for few seconds saying...

  • Eduardo Calles Eduardo Calles posted a comment on discussion Help

    Hello I just grab the driver "omronEthernetFINSCom1" and place it on my Form1 project on Visual Studio C# project. I typed my address of my PLC on the IP address, But, I am not so sure what is the format of my tag, For example on the CX-Programmer, my tag address is 3.13, so I just type 3.13 for my PLCAddressSelectColor2 for my BasicIndicator properties, but this is not working. When I play the application, my indicator doesn't show the correct state, but it shows a message for few seconds saying...

  • AdvancedHMI AdvancedHMI released /advancedhmi/3.5/SampleProjects/LargePressHMIonPanelPC.zip

  • Archie Archie posted a comment on discussion Help

    You may want to post on the official AdvancedHMI forum. It has much more users watching it. For the MessageDisplayByBit, you set the following properties: PLCAddressValues (e.g. N7:0) PLCElementBitWidth (e.g. 16) PLCNumberOfElements (e.g. 2 for 2 words of bits) You then go into the Messages property and define each message and indicate its corresponding bit

  • Jeff K Jeff K posted a comment on discussion Help

    I am new to HMI development. I am using Advanced HMI with RS Logix Micro. I would like to display text (representing alarms) when a specific bit is set. I have found some discussions on the subject but they are just a little advanced for me. I have tried use MessageDisplayByBit and I am missing some step in how to use it. Is there step by step insturctions that I can access? Thank you.

  • Archie Archie posted a comment on discussion Help

    Please post questions on the forum at the AdvancedHMI web site. It is where the experts monitor ona regular basis

  • Henny Henny posted a comment on discussion Help

    Please could you provide me information for communication by Modbus TCP. To communicate with a WAGO PLC (Codesys V2.3)

  • RODYan00 RODYan00 modified a comment on discussion Help

    HI I did so chart chart is at 100 points How Can I solve this problem? thanks best regard Private Sub Timer1_Tick(sender As System.Object, e As System.EventArgs) Handles Timer1.Tick Dim Value As Integer '* Add

  • RODYan00 RODYan00 posted a comment on discussion Help

    HI I did so chart chart is at 100 points Private Sub Timer1_Tick(sender As System.Object, e As System.EventArgs) Handles Timer1.Tick Dim Value As Integer Try Value = ModbusRTUCom1.Read("41914", 1)(0) Catch ex As Exception Exit Sub End Try '* Add the next point to the chart ChartBySampling1.Series(0).Points.Add(Value) '* Do not let more than 100 point be on the chart If ChartBySampling1.Series.Count > 100 Then ChartBySampling1.Series(0).Points.RemoveAt(0) End If End Sub

  • Dhananjay Joshi Dhananjay Joshi posted a comment on discussion Help

    Ok, I understand, I saw Timings on forum page :). Counters and Timers go to oveflow Exception after subscription. while Booleans go to next Tag instead of Bit (B3:1, B3:2 instead of B3:1/0, B3:1/1). I'll work with forum then, Thanks.

  • Archie Archie posted a comment on discussion Help

    The one thing you could try is to add a BasicLabel to the form and set PLCAddressValue to an addres that you say is not working, then run the application. All of the visual controls use the subscription mechanism, so it will prove out that it works or give an error to indicate the problem.

  • Archie Archie posted a comment on discussion Help

    It is still early here in North America so it may be a few hours before anyone sees the post. I am unable to check into it today because I will be giving a training class all day.

  • Dhananjay Joshi Dhananjay Joshi posted a comment on discussion Help

    Hi Archie, Can you may be just ping some expert to respond on Forum where I have posted my question again. Please. I am on a clock...

  • Dhananjay Joshi Dhananjay Joshi posted a comment on discussion Help

    I followed this but does not work with Timers, Booleans or Counters. Any way I'll raise it in forum.

  • Archie Archie posted a comment on discussion Help

    This could provide your answer, but the expert on the SLC/Micro frequents the forum. https://advancedhmi.com/documentation/index.php?title=Subscribing_to_PLC_data_via_code

  • Dhananjay Joshi Dhananjay Joshi posted a comment on discussion Help

    Hi Archie, I just need 2 Lines of code fore referencing to correct my logic. I need correct var Timers = Connection.Subscribe("Timertag", 50,100ms, Subscribedevent); var Counters= Connection.Subscribe("CounterTag", 50,100ms, Subscribedevent); var BooleanBits = Connection.Subscribe("BooleanBitTag(eg. B3:0/1)", 50,100ms, Subscribedevent); If you can give me that My problems will be fixed. Nothing more to discuss. Is it Still necessary to go to the forum? Greatwork BTW with Advanced HMI!

  • Archie Archie posted a comment on discussion Help

    If you post this on the official forum, you will get more responses: https://www.advancedhmi.com/forum/index.php

  • Dhananjay Joshi Dhananjay Joshi posted a comment on discussion Help

    I am using AdvancedHMIv399x. I am not using any UI Controls, I am just using EthernetIPforSLCMicroCom.Read and Write. Recently I came across the Subscribe Event where PLC Polls Data after a Declare Time Interval. This will save me a Lot of Time for updating Values from PLC as 1by1 fetching Tags takes 10 ms (Specified on some other discussion). I can Fetch all Real bits normally with subscription but unable to work with Boolean Tags like B3:10/0-1-2-3 etc. and Timer valueslike T4:9.PRE, ACC, EN,DN...

  • AdvancedHMI AdvancedHMI released /advancedhmi/3.5/AdvancedHMIV399xPatched3.zip

  • AdvancedHMI AdvancedHMI released /advancedhmi/3.5/AdvancedHMIv399xPatched2.zip

  • Archie Archie posted a comment on discussion Help

    Are you trying to write more than 1 elements? That error typically comes from writing beyond the length of the data file. You also may want to post your question on the AdvancedHMI forum where you will get more responses.

  • Aravind Hari Aravind Hari posted a comment on discussion Help

    I am trying to write a value to a tag address in Micrologix 1400 PLC through c# using MfgControl.AdvancedHMI.Drivers.dll. while writing the following error is thrown: Illegal Command or Format, Address may not exist or not enough elements in data file, StackTrace- at AdvancedHMIDrivers.AllenBradleyPCCC.WriteRawData(PCCCAddress PAddressO, Int32 numberOfBytes, Byte[] dataToWrite) at AdvancedHMIDrivers.AllenBradleyPCCC.WriteData(String startAddress, Int32 numberOfElements, Int32[] dataToWrite) at AdvancedHMIDrivers.AllenBradleyPCCC.WriteData(String...

  • Ronald Pennings Ronald Pennings posted a comment on discussion Open Discussion

    Should I be using a null modem cable or a straight through cable

  • Ronald Pennings Ronald Pennings posted a comment on discussion Open Discussion

    Hi and thanks for that, you have built the same project as i am trying to! except yours works! I must have a slightly different version of hmi as it will only let me have a poll rate override value of 500bits??? any suggestions?

  • cjawood cjawood posted a comment on discussion Open Discussion

    .

  • cjawood cjawood posted a comment on discussion Open Discussion

    .

  • AdvancedHMI AdvancedHMI released /advancedhmi/3.5/AdvancedHMIv399xPatched.zip

  • AdvancedHMI AdvancedHMI released /advancedhmi/3.5/SampleProjects/DesignerFormInVisualStudioR1.zip

  • AdvancedHMI AdvancedHMI released /advancedhmi/3.5/SampleProjects/DesignerFormInVisualStudio.zip

  • AdvancedHMI AdvancedHMI released /advancedhmi/3.5/SampleProjects/GlobalsExample.zip

  • AdvancedHMI AdvancedHMI released /advancedhmi/3.5/SampleProjects/KeepingRecordsfromCLXToExcelV399x.zip

  • AdvancedHMI AdvancedHMI released /advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.DriversPatch8V399x.zip

  • AdvancedHMI AdvancedHMI released /advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.DriversPatch7V399x.zip

  • AdvancedHMI AdvancedHMI released /advancedhmi/3.5/Patches/AdvancedHMIDriversV399xPatch5.zip

  • AdvancedHMI AdvancedHMI released /advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.DriversPatch5V399x.zip

  • AdvancedHMI AdvancedHMI released /advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.DriversPatch4V399x.zip

  • AdvancedHMI AdvancedHMI released /advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.DriversPatch3V399x.zip

  • AdvancedHMI AdvancedHMI released /advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.DriversPatch2V399x.zip

  • AdvancedHMI AdvancedHMI released /advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.DriversPatch1V399x.zip

  • AdvancedHMI AdvancedHMI released /advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.ControlsV399xPatch1.zip

  • AdvancedHMI AdvancedHMI released /advancedhmi/3.5/AdvancedHMIv399x.zip

  • AdvancedHMI AdvancedHMI released /advancedhmi/3.5/Advanced HMI V3.99x

  • AdvancedHMI AdvancedHMI released /advancedhmi/3.5/AdvancedHMIv399x.zip

  • Advanced HMI Advanced HMI released /advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.DriversPatch4V399w.zip

  • Advanced HMI Advanced HMI released /advancedhmi/3.5/SampleProjects/AdvancedHMIv35MsgByValueColorDemo.zip

  • Advanced HMI Advanced HMI released /advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.DriversPatch3V399w.zip

  • Advanced HMI Advanced HMI released /advancedhmi/3.5/SampleProjects/UserControlTest.zip

  • Advanced HMI Advanced HMI released /advancedhmi/3.5/SampleProjects/AlarmButtonDemo.zip

  • Mark Marusich Mark Marusich posted a comment on discussion Open Discussion

    I have downloaded the Advanced HMI File (Version 3.5). When trying to open in Visual...

  • Advanced HMI Advanced HMI released /advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.ControlsV399wPatch3.zip

  • Advanced HMI Advanced HMI released /advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.ControlsV399wPatch2.zip

  • Advanced HMI Advanced HMI released /advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.ControlsV399wPatch1.zip

  • Advanced HMI Advanced HMI released /advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.DriversPatch1V399w.zip

  • Nilesh Nilesh modified a comment on discussion Help

    Thanku so much Archi. I will make the form hide. and it dosent gives the details...

  • Nilesh Nilesh posted a comment on discussion Help

    ok i will make the form hide. but it dosent gives the details of class and line ...

  • Archie Archie posted a comment on discussion Help

    It's better to hide the form so it does not have to reload every time. When you get...

  • Nilesh Nilesh posted a comment on discussion Help

    AdvancedHMIv399t. Visual Studio 2010. I am not hiding the form im closing it.