Start your next project with $300 in free Google Cloud credit. Spin up VMs, run containers, query petabytes in BigQuery, or build agents with Gemini Enterprise Agent Platform. Once your credits are used, keep building with 20+ always-free tier products including Compute Engine, Cloud Storage, GKE, and Cloud Run functions. No commitment required—just sign up and start building.
A C Program code to solve for Heat diffusion in 3D Axi-symmetric grid.
Type - 3D
Grid - Axisymmetric
Case - Heat diffusion
Method - Finite Volume Method
Approach - Flux based
Accuracy - First order
Scheme - Explicit
Temporal - Unsteady
Parallelized - No
Inputs:
[
Length of domain (LR,LZ,LH)
Time step - DT
Material properties - Conductivity (k or kk)
Density - (rho)
Heat capacity - (cp)
Boundary condition and Initial condition.
]
Setup -
Periphery heated to 500 C
Top to 500 C
Bottom to 500 C
A C Program code to solve for Heat diffusion in 2D Axi-symmetric grid.
Type - 2D
Grid - Axisymmetric
Case - Heat diffusion
Method - Finite Volume Method
Approach - Flux based
Accuracy - First order
Scheme - Explicit
Temporal - Unsteady
Parallelized - No
Inputs:
[
Length of domain (LR,LZ)
Time step - DT
Material properties - Conductivity (k or kk)
Density - (rho)
Heat capacity - (cp)
Boundary condition and Initial condition.
]
Setup -
Periphery heated to 200 C
Top to 300 C