JeromePilot

Show:

What's happening?

  • Comment: probe trips message while G38.2 or G38.3

    I've add a debounce to my hal file, even with a small number it seems to be working. You were right about a noiy signal.

    2013-04-16 13:29:15 PDT in Enhanced Machine ...

  • Comment: probe trips message while G38.2 or G38.3

    You are probaly right even if with the scope it's not very clear. After grounding everything, changing the power supply, i tried to find a software improvement adding a timer but up to now it's not 100 % working. A g38 choosen without error code was looking like an answer :o)

    2013-02-22 12:35:56 PST in Enhanced Machine ...

  • probe trips message while G38.2 or G38.3

    With 2.5.1, with 2 different controlers , I want to use the G38.2 or the G38.3 G-code to set the zero of my machines. The movement and touching detection is OK BUT I have sometime (more than 50%) an error message just when contacts saying me that the probe trips during a non-probe MDI command. But the G38 is a probe MDI command I think ?!??.

    2013-02-13 10:45:33 PST in Enhanced Machine ...

About Me

  • 2013-02-13 (3 months ago)
  • 4155614
  • jeromepilot22 (My Site)
  • JeromePilot

Send me a message