Tracker: OBI Terms

7 instument clean up - processed material - ID: 2855265
Last Update: Comment added ( mcourtot )

The instrument branch is in need of clean up, which hasn't been done since
the MSI import.


melanie ( mcourtot ) - 2009-09-09 15:32

7

Open

None

bjoernpeters

cleanup

instruments

Public


Comments ( 8 )

Date: 2009-11-09 23:21
Sender: mcourtotProject Admin

thanks for update - I had missed that class. I suspect next in line is
update subclasses with their function to get proper classification. Would
probably help to address
https://sourceforge.net/tracker/?func=detail&atid=886178&aid=2894801&group_id=177891.
I'll add the note to the obsolete_device class.


Date: 2009-11-09 23:04
Sender: bjoernpeters

MC: Your notes are not what I recollect. device was deprecated
intentionally, precisely because the 'manufacturing' definition does not
really help at all (some reagents are manusfactured. some 'devices' are
not. HP's notes below are accurate.


Date: 2009-11-09 21:39
Sender: mcourtotProject Admin

We currently have neither device nor instrument in the file. I had kept
from the workshop notes that we would keep device and define it as "device
= material entity and is specified output of manufacturing process"
I am not sure what is the current status. Note that the term device is
used widely in labels, definitions etc.




Date: 2009-10-28 15:43
Sender: mcourtotProject Admin

+ check restrictions on device


Date: 2009-10-22 05:15
Sender: parkinso

instrument no longer exists, replaced by parent class processed material,
device also removed and replaced by measurement device defined class. more
work to do after cleanup workshop here adding new defined classes, cleaning
existing definitions and labels. also all MSI terms need logical defs,
classification classes by function removed and added as editor notes


Date: 2009-10-05 03:46
Sender: bjoernpeters

Fixed the tubes by creating a parent class (test tube), and specified more
specifically that 'collection tube' as defined referred to a 'cell sorter
collection tube'. Making more specific labels will probably have to be done
for the entirety of devices.


Date: 2009-09-23 19:39
Sender: parkinso

collection tube, is a part of fluidics sytems, but is modelled as is-a
device. probably needs to renamed fluidics system collection tube and the
part of corrected.


Date: 2009-09-23 13:50
Sender: parkinso

e.g. sample tube - is a represented as a subclass of 'piezo electric
crystal' which itself is part of a sorter, sample tube inherits therefore
'perturbe function' which is a. spelled wrongly and b. should probably be
part of some 'sorter' rather than the crystal itself


Attached File

No Files Currently Attached

Changes ( 2 )

Field Old Value Date By
priority 8 2009-10-28 15:36 bjoernpeters
summary instument clean up 2009-10-22 05:15 parkinso