Share

jAudio

Tracker: Bugs

5 Sample Rate 22050 Hz doesn't work - ID: 1740460
Last Update: Settings changed ( mcennis )

Setting the Sample Rate to 22,05 KHz (Analysis->Sample Rate (kHz)->22.05)
causes jAudio to stop Feature extraction immediately.
(ERROR: "invalid output index: output.length=22052 outByteOffset=2
samplecount=5513 format=26: 16bit signed big endian")


Nobody/Anonymous ( nobody ) - 2007-06-20 16:33

5

Closed

Accepted

Daniel McEnnis

None

None

Public


Comments ( 2 )




Date: 2008-01-28 22:15
Sender: mcennisProject AdminAccepting Donations


A corrupted jar file seems to be the problem. A corrected version is
uploaded. Still tracking down how the corrupted jar file made it into the
system....


Date: 2007-06-20 16:43
Sender: nobody

Logged In: NO

The original file (mp3) is recorded at 44100 Hz


Log in to comment.

Attached File

No Files Currently Attached

Changes ( 8 )

Field Old Value Date By
status_id Open 2008-01-28 22:16 mcennis
close_date - 2008-01-28 22:16 mcennis
resolution_id None 2007-11-12 03:44 mcennis
close_date 2007-11-11 23:40 2007-11-12 03:44 mcennis
assigned_to nobody 2007-11-12 03:44 mcennis
status_id Pending 2007-11-12 03:44 mcennis
status_id Open 2007-11-11 23:40 mcennis
close_date - 2007-11-11 23:40 mcennis