#15 Network protocol does not support repeating ir commands

closed
nobody
None
5
2012-02-08
2011-12-28
No

Hi

I have sony tv which needs at least one repetition of the ir command before it is registered. Thats easy using winlirc directly (set repeat to 1 at the main window) but I am uncertain how to do it through the network protocol, SEND_START/SEND_STOP isn't supported, is it? And just sending the code twice using SEND_ONCE does not work. I think the delay between the two commands is greater than allowed, therefore it does not help to add additional delay between sending.

Best regards
Martin

Discussion

  • Ian
    Ian
    2011-12-29

    I just checked, you are right it doesn't support sending repeats via SEND_ONCE
    it should do but doesn't. I can try and fix this in later builds.

     
  • Ian
    Ian
    2012-02-08

    • status: open --> closed
     
  • Ian
    Ian
    2012-02-08

    Fixed in newest build.