#2 V4L shuts down immediately after starts

Bug
closed-fixed
nobody
General (2)
5
2001-03-30
2001-03-26
Anonymous
No

file: V4L++.cc

method: V4L::init
needs the following line of code added to it:

m_stop_request = false;

---------------------------

The problem I had was that V4L would shut down
almost immediately after polled mode was started.

This is due to uninitialized memory, which sometimes
was
o.k.

Mike

Discussion

  • Logged In: NO

    I was informed by the project administrator that this will
    be fixed and updated soon. In the meantime, users are
    encouraged to add the
    line of code themselves and recompile.

     
  • Logged In: YES
    user_id=57990

    Addressed in latest release.

     
    • status: open --> closed-fixed