#12 PCD Fails to terminate a terminated process

closed-fixed
Hai Shalom
process (2)
5
2010-10-30
2010-10-19
Anonymous
No

When a process terminates, and a request to terminate the same process arrives from PCD API, the PCD fails to detect it correctly, and results in delay of 10 seconds and then it tries to kill it with SIGKILL, although the process does not exist.

Discussion

  • Hai Shalom
    Hai Shalom
    2010-10-25

    • assigned_to: nobody --> hais
     
  • Hai Shalom
    Hai Shalom
    2010-10-30

    Process module now checks the return value of kill system call. If it fails, it will not wait for the process because it is already terminated.

     
  • Hai Shalom
    Hai Shalom
    2010-10-30

    • status: open --> closed-fixed