#1770 Wrong OA FW Version is displayed by openhpi clients

3.2.1
closed-fixed
5
2013-06-20
2012-10-19
Shyamala
No

Wrong OA FW Version is displayed by openhpi clients (hpi_shell and hpitree). The correct OA FW Version is 3.56 but hpi_shell shows wrongly as below.

[root@dl380g52-4 logs]# hpi_shell
hpi_shell - This program came with OpenHPI 3.3.0
SAF HPI Version B.03.02

Discovery done
Enter a command or "help" for list of commands
Available commands are:
addcfg ann clearevtlog ctrl
dat debug dimi domain
domaininfo drt dscv echo
entinstr entres event evtlogtime
evtlogreset evtlogstate exec fumi
help history hs inv
lsent lsres lsensor more
newdomain parmctrl power quit
rdr rdrupdatecounter reopen removefailed
reset rpt run sen
settag setsever settimeevtlog showevtlog
showinv showrdr showrpt ver
wdtget wdtreset wdtset ?

hpi_shell> rpt
(001):BladeSystem c7000 Enclosure:{S|RDR|INV|CNT|RES}
(003):ProLiant BL460c G1:{S|RDR|INV|RST|PWR|FRU|CNT|HS|RES}
(005):ProLiant BL460c G1:{S|RDR|INV|RST|PWR|FRU|CNT|HS|RES}
(017):GbE2c Ethernet Blade Switch:{S|RDR|INV|RST|PWR|FRU|CNT|HS|RES}
(018):GbE2c Ethernet Blade Switch:{S|RDR|INV|RST|PWR|FRU|CNT|HS|RES}
(020):HP 1/10Gb VC-Enet Module:{S|RDR|INV|RST|PWR|FRU|CNT|HS|RES}
(021):Thermal Subsystem:{S|RDR|RES}
(022):Fan Zone:{S|RDR|INV|RES}
(023):Fan Zone:{S|RDR|INV|RES}
(024):Fan Zone:{S|RDR|INV|RES}
(025):Fan Zone:{S|RDR|INV|RES}
(026):Fan:{S|RDR|INV|FRU|RES}
(027):Fan:{S|RDR|INV|FRU|RES}
(028):Fan:{S|RDR|INV|FRU|RES}
(029):Fan:{S|RDR|INV|FRU|RES}
(030):Fan:{S|RDR|INV|FRU|RES}
(031):Fan:{S|RDR|INV|FRU|RES}
(032):Fan:{S|RDR|INV|FRU|RES}
(033):Fan:{S|RDR|INV|FRU|RES}
(034):Fan:{S|RDR|INV|FRU|RES}
(035):Fan:{S|RDR|INV|FRU|RES}
(036):Power Subsystem:{S|RDR|CNT|RES}
(037):Power Supply Unit:{S|RDR|INV|FRU|RES}
(038):Power Supply Unit:{S|RDR|INV|FRU|RES}
(040):Power Supply Unit:{S|RDR|INV|FRU|RES}
(041):Onboard Administrator:{S|RDR|INV|FRU|CNT|RES}
(042):Onboard Administrator:{S|RDR|INV|FRU|CNT|RES}
(043):LCD:{S|RDR|INV|CNT|RES}
RPT ID ==> 41
EntryId: 41
ResourceId: 41
ResourceInfo:
ResourceRev: 0
SpecificVer: 0
DeviceSupport: 0
ManufacturerId: 11 (0x0000000b)
ProductId: 0
FirmwareMajorRev: 4
FirmwareMinorRev: 212
AuxFirmwareRev: 0
Guid: 00000000-0000-0000-0000-000000000000
ResourceEntity: {SYSTEM_CHASSIS,8}{SYS_MGMNT_MODULE,1}
Capabilities: CONTROL | FRU | INVENTORY_DATA | RDR | RESOURCE | SENSOR
HotSwapCapabilities: None
ResourceSeverity: OK
ResourceFailed: FALSE
Tag: TEXT: ENGLISH: Onboard Administrator (len=21)
hpi_shell>
hpi_shell> rpt 42
EntryId: 42
ResourceId: 42
ResourceInfo:
ResourceRev: 0
SpecificVer: 0
DeviceSupport: 0
ManufacturerId: 11 (0x0000000b)
ProductId: 0
FirmwareMajorRev: 4
FirmwareMinorRev: 212
AuxFirmwareRev: 0
Guid: 00000000-0000-0000-0000-000000000000
ResourceEntity: {SYSTEM_CHASSIS,8}{SYS_MGMNT_MODULE,2}
Capabilities: CONTROL | FRU | INVENTORY_DATA | RDR | RESOURCE | SENSOR
HotSwapCapabilities: None
ResourceSeverity: OK
ResourceFailed: FALSE
Tag: TEXT: ENGLISH: Onboard Administrator (len=21)
hpi_shell>

And hpitree displays FW version in two places, in one place it (PRODUCT_VERSION) is correct and other place it is wrong.

Entity Path: {SYSTEM_CHASSIS,8}{SYS_MGMNT_MODULE,1}
EntryId: 41
ResourceId: 41
Resource Information:
Manufacturer ID: Hewlett-Packard
Firmware Major Revision: 4
Firmware Minor Revision: 212
Entity Path: {SYSTEM_CHASSIS,8}{SYS_MGMNT_MODULE,1}
Capabilities:
CONTROL | FRU | INVENTORY_DATA | RDR | RESOURCE | SENSOR
HotSwap Capabilities: None
Resource Severity: OK
ResourceFailed: FALSE
ResourceTag:
Data Type: TEXT
Language: ENGLISH
Data Length: 21
Data: Onboard Administrator

RecordId: 196608
RdrType: INVENTORY_RDR
Entity Path: {SYSTEM_CHASSIS,8}{SYS_MGMNT_MODULE,1}
IsFru: FALSE
IdrId: 0
Persistent: FALSE
Oem: 0
IdString:
Data Type: TEXT
Language: ENGLISH
Data Length: 39
Data: BladeSystem c7000 Onboard Administrator

IdrId: 0
UpdateCount: 1
ReadOnly: FALSE
NumAreas: 2

AreaId: 1
AreaType: PRODUCT_INFO
ReadOnly: FALSE
NumFields: 3

Field Id: 1
Field Type: PRODUCT_NAME
ReadOnly: FALSE
Data Type: TEXT
Language: ENGLISH
Content: BladeSystem c7000 Onboard Administrator
Field Id: 2
Field Type: MANUFACTURER
ReadOnly: FALSE
Data Type: TEXT
Language: ENGLISH
Content: HP
Field Id: 3
Field Type: PRODUCT_VERSION
ReadOnly: FALSE
Data Type: TEXT
Language: ENGLISH
Content: 3.56

Discussion

  • Fixed in Revision #7523

     
    • assigned_to: dr_mohan --> hemanthreddy
    • status: open --> open-fixed
     
    • status: open-fixed --> closed-fixed
     
  • Closing the Bug As it is Fixed in Rev:7523

     
  • dr_mohan
    dr_mohan
    2013-06-20

    • Group: 3.3.x --> 3.2.1
     
  • Tariq Shureih
    Tariq Shureih
    2013-06-20

    *ATTENTION**