#1259 Fix logic value returned for unambiguous HiZ1 strength

closed
nobody
None
5
2013-01-29
2013-01-28
Martin Whitaker
No

Stumbled across this whilst trying to create a simple test for br918. If a strength aware net has an unambiguous HiZ1 strength, VVP treats it as a logic '1'. It should be treated as a logic 'z'. An ambiguous HiZ1/HiZ0 strength should also be treated as a logic 'z'.

This patch can be applied to both devel and v0.9.

1 Attachments

Discussion

  • Here is a regression test for the test suite.

     
    Attachments
  • Cary R.
    Cary R.
    2013-01-29

    • status: open --> closed
     
  • Cary R.
    Cary R.
    2013-01-29

    Thanks Martin. I'm applying this to both development and V0.9.