#19 Bug in main screen

closed-fixed
Paul Mueller
GUI (14)
5
2007-02-02
2005-03-20
Paul Mueller
No

- Info about unit is displayed two times. One time at
the correct postion, one time at the left top of the
screen.
- Unit has to be clicked on before it can be moved,
despite of cursor at correct position.

Discussion

  • Paul Mueller
    Paul Mueller
    2005-04-09

    Logged In: YES
    user_id=128557

    Info about unit is only displayed once. But still at the
    left top of the screen.
    Unit movement still not works correct :(.

     
  • Paul Mueller
    Paul Mueller
    2005-11-08

    Logged In: YES
    user_id=128557

    Unit info is again dispalyed twice. Depends on input. Still
    looking up why it doesn't work.

     
  • Paul Mueller
    Paul Mueller
    2006-03-08

    Logged In: YES
    user_id=128557

    Display code is to be rewritten. Code is rewritten. Display
    for unit info gets a new solution.

     
  • Paul Mueller
    Paul Mueller
    2006-03-13

    Logged In: YES
    user_id=128557

    Unit info isn't displayed at all. Check for drawing of
    Labels needed - maybe not called at all.

     
  • Paul Mueller
    Paul Mueller
    2007-02-02

    • status: open --> closed-fixed
     
  • Paul Mueller
    Paul Mueller
    2007-02-02

    Logged In: YES
    user_id=128557
    Originator: YES

    Unit is now displayed only once, but the position of the strings look a little bit strange.