smartctl 5.39 2009-03-23 21:59 [i686-pc-mingw32-xp-sp3] (cf-win32-20090323) Copyright (C) 2002-9 by Bruce Allen, http://smartmontools.sourceforge.net === START OF INFORMATION SECTION === Model Family: SAMSUNG SpinPoint P80 series Device Model: SAMSUNG SP1614N Serial Number: .... (private information) Firmware Version: TM100-24 User Capacity: 160 041 885 696 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 7 ATA Standard is: ATA/ATAPI-7 T13 1532D revision 0 Local Time is: Fri Feb 11 18:12:01 2011 WN SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (5760) seconds. Offline data collection capabilities: (0x1b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. No Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. No General Purpose Logging support. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 96) minutes. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000b 100 100 051 Pre-fail Always - 0 3 Spin_Up_Time 0x0007 253 253 000 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 253 253 000 Old_age Always - 0 5 Reallocated_Sector_Ct 0x0033 253 253 010 Pre-fail Always - 0 7 Seek_Error_Rate 0x000b 253 253 051 Pre-fail Always - 0 8 Seek_Time_Performance 0x0024 253 253 000 Old_age Offline - 0 9 Power_On_Half_Minutes 0x0032 253 253 000 Old_age Always - 0h+33m 10 Spin_Retry_Count 0x0013 253 253 049 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 253 253 000 Old_age Always - 0 194 Temperature_Celsius 0x0022 163 163 000 Old_age Always - 25 195 Hardware_ECC_Recovered 0x000a 100 100 000 Old_age Always - 179118 196 Reallocated_Event_Count 0x0012 253 253 000 Old_age Always - 0 197 Current_Pending_Sector 0x0033 253 253 010 Pre-fail Always - 0 198 Offline_Uncorrectable 0x0031 253 253 010 Pre-fail Offline - 0 199 UDMA_CRC_Error_Count 0x000b 253 253 051 Pre-fail Always - 0 200 Multi_Zone_Error_Rate 0x000b 253 253 051 Pre-fail Always - 0 201 Soft_Read_Error_Rate 0x000b 253 253 051 Pre-fail Always - 0 SMART Error Log Version: 1 ATA Error Count: 13 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 13 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 04 51 01 06 4f c2 a0 Error: ABRT Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- b0 d5 01 06 4f c2 a0 00 00:14:25.438 SMART READ LOG Error 12 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 04 51 01 01 4f c2 a0 Error: ABRT Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- b0 d5 01 01 4f c2 a0 00 00:14:25.375 SMART READ LOG Error 11 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 04 51 01 01 4f c2 a0 Error: ABRT Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- b0 d1 01 01 4f c2 a0 00 00:14:25.375 SMART READ ATTRIBUTE THRESHOLDS [OBS-4] Error 10 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 04 51 01 00 4f c2 a0 Error: ABRT Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- b0 d0 01 00 4f c2 a0 00 00:14:25.313 SMART READ DATA Error 9 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 04 51 00 00 4f c2 a0 Error: ABRT Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- b0 da 00 00 4f c2 a0 00 00:14:25.250 SMART RETURN STATUS SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 0 - Device does not support Selective Self Tests/Logging