hi all,
Im using smartmontools-5.37, and i try to run
short selftest in my Hitachi hard disk connected to 3w_9xxx hardware
raid controller card.After completing the test i cont able to access my
hard disk (i.e
) i cont able to create raid on that hard disk. And I'm getting some
warning after the SMART Self-test log structure revision, the warning
message are
Warning! SMART Selective Self-Test Log Structure error: invalid SMART
checksum.
SMART Selective self-test log data structure revision number 1.
I hereby display the command issued by me and the output.
-Command# /usr/local/sbin/smartctl -t short -d 3ware,1 /dev/twa0
smartctl version 5.37 [i686-pc-linux-gnu] Copyright (C) 2002-6 Bruce Allen
Home page is
http://smartmontools.sourceforge.net/
OUTPUT: === START OF OFFLINE IMMEDIATE AND SELF-TEST SECTION ===
Sending command: "Execute SMART Short self-test routine immediately in off-line mode".
Command "Execute SMART Short self-test routine immediately in off-line mode" failed: Input/output error
command:# /usr/local/sbin/smartctl -a -d 3ware,1 /dev/twa0
oUTPUT: smartctl version 5.37 [i686-pc-linux-gnu] Copyright (C) 2002-6 Bruce Allen
Home page is
http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Model Family: Hitachi Deskstar 7K500 series
Device Model: HDS725050KLA360
Serial Number: KRVN63ZAHYHYSD
Firmware Version: K2AOAD1A
User Capacity: 500,107,862,016 bytes
Device is: In smartctl database [for details use: -P show]
ATA Version is: 7
ATA Standard is: ATA/ATAPI-7 T13 1532D revision 1
Local Time is: Mon Jun 18 20:57:09 2007 IST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x02) Offline data collection activity